UPS ENERTRONIC Modular SE

UPS systems with modular plug-in technology - ENERTRONIC modular SE

Highest availability at lowest operating costs
In particular for process-critical applications, the reliability of a UPS system must not be called into question by savings. By using high-quality components and generously dimensioning the components in the critical path, BENNING has succeeded in developing a UPS system that is optimally adapted to the harsh conditions of the industry. Each ENERTRONIC modular SE UPS module is a highly efficient online UPS (VFI-SS-111).
The combination of maximum reliability with the advantages of repair times optimized by “hot swap” modularity results in an availability of 99.9999%.

If higher performance is needed later, the ENERTRONIC modular SE can easily grow (pay as you grow). Together with the very high efficiency, even in the partial load range, the operating costs are minimized without compromising on the quality of supply. Since the supply of the consumers in the ENERTRONIC modular SE takes place via the DC and inverter, there is a significant improvement in the voltage and frequency quality.

Main features: UPS ENERTRONIC modular SE

  • maximum availability
    • very high reliability
    • very short repair time (MTTR)
    • Module exchange during operation
    • modular self-configuration for N + 1 redundancy
  • no single point of failure
    • redundant circuits in each module
    • Multi-master operation
    • decentralized parallel architecture
  • lowest operating costs
    • up to 96% efficiency in double conversion operation
    • up to 99% efficiency in SE mode
    • Simple system expansion up to 1000 kW
  • highest energy quality
    • UPS classification VFI-SS-111
    • Total Input Distortion (THDi) <3%
    • Input power factor ≥ 0.99
    • very high overload capacity
  • ● IGBT UPS technology (DC / inverter)
  • ● Three Phase
  • ● No single point of failure
  • ● Especially suitable for non-linear loads
  • ● Power range: 20 kW – 1000 kW
  • ● Input voltage: 380/400/415 V ± 15% (3ph + N + PE)
  • ● Output voltages: 380V, 400V, 415V
  • ● Compact, modular, reliable
  • ● Switching plan
  • ● Digital controller
  • ● Decentralized parallel architecture
  • ● N +1 redundancy
  • ● Self-sufficient modules
  • ● Extensive reporting and monitoring functions
  • ● Electronic switching device
  • ● Service bypass
  • ● Temperature-controlled charge
  • ● Battery availability test / battery circuit test
  • ● Good interference immunity / interference emission
  • ● High quality of the output power (parameter)

ENERTRONIC modular SE

  • ● Low network perturbations
  • ● Low residual ripple at the rectifier output
  • ● Low volume and weight
  • ● Energy efficient
  • ● Suitable for lead u. NiCd batteries
  • ● Low volume and weight
  • ● Easy adjustment of system performance
  • ● Hot plug
  • ● Plug and play
  • ● Energy efficient
  • ● Suitable for lead and NiCd batteries

Comparison of redundant ENERTRONIC modular SE systems with conventional redundant monobloc UPS systems

Comparison of redundant ENERTRONIC modular SE systems with conventional redundant monobloc UPS systems

Easy adjustment of system performance, examples …

40 kW (2 x 20 kW with integrated batteries)

  • Footprint: 1800mm x 600mm x 800mm
  • Power / Footprint: 83 kW / m 2

Comparison of redundant ENERTRONIC modular SE systems with conventional redundant monobloc UPS systems

100 kW (5 x 20 kW)

  • Footprint: 1800mm x 600mm x 800mm
  • Power / Footprint: 208 kW / m 2

Comparison of redundant ENERTRONIC modular SE systems with conventional redundant monobloc UPS systems

120 kW (6 x 20 kW)

  • Footprint: 2000mm x 600mm x 800mm
  • Power / Footprint: 250 kW / m 2

Comparison of redundant ENERTRONIC modular SE systems with conventional redundant monobloc UPS systems